作业帮 > 英语 > 作业

英语翻译We experienced some problems on trial-produced XXXX.Here

来源:学生作业帮 编辑:神马作文网作业帮 分类:英语作业 时间:2024/11/19 23:53:17
英语翻译
We experienced some problems on trial-produced XXXX.Here are the details:
The step H of the test procedure(see attached file) requested that “adjust the DC electronic load for the 2.5A and verify the +12V output shuts down and the +12 LED dims”.
However,when the electronic load was adjusted to 2.5A,the +12V output didn’t shut down and an around 2.7V voltage could be measured.
Please check and advise.
二,
All of the three XXXX boards which have changed materials according to the below e-mail’s requirement were failed to pass the test.
When the test ran to step 5.P of the test procedure(see attached file “TS-XXXXX.pdf”,on page 14),
a error message which said “writing to redundant Nand…FAILED” appeared in the hyper terminal program.Please refer to the attached "FAIL.JPG & Log file.txt” for details.
Incidentally,the 201559 boards that did not change materials could be passed the test.
英语翻译We experienced some problems on trial-produced XXXX.Here
We met some problems on trial-produce of XXXX.Details as below:
On the step H of the test procedure (see attached file) which requests that “adjust the DC electronic load for the 2.5A and verify the +12V output shuts down and the +12 LED dims”.
As we followed this instruction,however,when the electronic load was adjusted to 2.5A,the +12V output didn’t shut down and there was about 2.7V voltage measured.
Please check and advise following:
All of the three XXXX boards which changed materials as below e-mail’s requirement were failed on the test.
When the test ran to step 5.P of the test procedure (see attached file “TS-XXXXX.pdf”,on page 14),an error message “writing to redundant Nand…FAILED” appeared in the hyper terminal program.For details,please refer to the attached file "FAIL.JPG & Log file.txt” .
However,the 201559 boards which did not change materials passed on the test.