4.19 Isolation Resistance.隔离电阻
来源:学生作业帮 编辑:神马作文网作业帮 分类:英语作业 时间:2024/09/26 00:19:16
4.19 Isolation Resistance.隔离电阻
4.19.4 Procedure.
Note:For sealed connector pairs,complete all measurements
in this test procedure within one hour after
any previous environmental test.
Note:For unsealed connector pairs,test samples
shall rest at ambient temperature and humidity for
3 h min.prior to measuring isolation resistance after
any previous environmental test.
1 Mate connector pairs.
2 Wrap metal foil around the exterior of the connector
without contacting any terminals or wires.
3 Remove a minimal amount of insulation from the
ends of the wires.
4 Separate wires under test with sufficient distance
as to have no influence on isolation resistance
between any two wire pairs.
5 Measure the isolation resistance by applying
500 VDC between all adjacent pairs of terminals.
6 Record the resistance after 15 s of stabilized readings.
7 Attach all the terminated wire leads to the positive
lead of a Mega-Ohmmeter.Attach the negative
lead of the Mega-Ohmmeter to the metal foil.
8 Measure the isolation resistance by applying
500 VDC between the terminals and the metal foil.
9 Record the resistance after 15 s of stabilized readings.
4.19.5 Acceptance Criteria.All measured isolation
resistances shall be > 100 M .
4.19.4 Procedure.
Note:For sealed connector pairs,complete all measurements
in this test procedure within one hour after
any previous environmental test.
Note:For unsealed connector pairs,test samples
shall rest at ambient temperature and humidity for
3 h min.prior to measuring isolation resistance after
any previous environmental test.
1 Mate connector pairs.
2 Wrap metal foil around the exterior of the connector
without contacting any terminals or wires.
3 Remove a minimal amount of insulation from the
ends of the wires.
4 Separate wires under test with sufficient distance
as to have no influence on isolation resistance
between any two wire pairs.
5 Measure the isolation resistance by applying
500 VDC between all adjacent pairs of terminals.
6 Record the resistance after 15 s of stabilized readings.
7 Attach all the terminated wire leads to the positive
lead of a Mega-Ohmmeter.Attach the negative
lead of the Mega-Ohmmeter to the metal foil.
8 Measure the isolation resistance by applying
500 VDC between the terminals and the metal foil.
9 Record the resistance after 15 s of stabilized readings.
4.19.5 Acceptance Criteria.All measured isolation
resistances shall be > 100 M .
4.19.4程序.
注:对于密封连接器对,完成所有的测量
在这个测试过程后一小时内
以往任何环境的考验.
注:对于非密封连接器对,测试样品
其余应在环境温度和湿度
3小时分钟.绝缘电阻测量之前后
以往任何环境的考验.
一对伴侣连接.
2环绕连接器的外观金属箔
没有接触任何终端或电线.
3从少量的绝缘
两端的导线.
4个单独的线下有足够的距离试验
以不会对绝缘电阻的影响
任何两个线对之间.
5测量采用绝缘电阻
500伏的终端之间的所有相邻对.
6记录经过15年的稳定读数的抵抗力.
7附上所有终止的积极引线
带领一百万欧姆表.附加的负面
在百万欧姆表导致金属箔.
8测量采用绝缘电阻
500伏之间的终端和金属箔.
9条记录的读数经过15年的稳定的抵抗力.
4.19.5验收标准.所有测量隔离
电阻应“100米.
注:对于密封连接器对,完成所有的测量
在这个测试过程后一小时内
以往任何环境的考验.
注:对于非密封连接器对,测试样品
其余应在环境温度和湿度
3小时分钟.绝缘电阻测量之前后
以往任何环境的考验.
一对伴侣连接.
2环绕连接器的外观金属箔
没有接触任何终端或电线.
3从少量的绝缘
两端的导线.
4个单独的线下有足够的距离试验
以不会对绝缘电阻的影响
任何两个线对之间.
5测量采用绝缘电阻
500伏的终端之间的所有相邻对.
6记录经过15年的稳定读数的抵抗力.
7附上所有终止的积极引线
带领一百万欧姆表.附加的负面
在百万欧姆表导致金属箔.
8测量采用绝缘电阻
500伏之间的终端和金属箔.
9条记录的读数经过15年的稳定的抵抗力.
4.19.5验收标准.所有测量隔离
电阻应“100米.
We also can check for contact isolation and resistance thres